What Does an Electric Heat Strip Do Inside a Tishomingo Air Handler?

An electric heat strip adds heat to the air moving through your indoor air handler. In a heat pump system, it usually provides backup heat when the outdoor unit can’t meet the home’s heating needs by itself. It may also help during defrost cycles or provide emergency heat if the heat pump stops working.

If you’re looking into electric heat strips in Tishomingo, MS, you’ve probably noticed “AUX” on the thermostat, felt hotter air coming from the vents, or opened an unexpectedly high electric bill. Those clues are worth understanding, but none automatically means something is broken.

The main distinction is simple: a heat pump moves heat, while a heat strip makes heat using electrical resistance. That difference explains both its usefulness and its electrical demand.

What’s Actually Inside the Air Handler?

The air handler is the indoor cabinet containing the blower and indoor refrigerant coil. If electric backup heat is installed, it also contains an approved heater assembly, often called a heat kit. Not every air handler has one.

Inside that assembly are resistance heating elements. Electricity passes through those elements, making them hot, and the blower carries that heat into the ductwork. The principle resembles an electric toaster, though an HVAC heat kit has its own controls, supports, and temperature safety devices.

Depending on the equipment, the elements may operate in stages rather than all switching on together. Relays or sequencers control when the heating circuits energize. Safety limits interrupt heating if temperatures rise beyond the equipment’s allowed range.

Heat strips depend on proper airflow. They can’t deliver heat safely without enough air moving across them. A clogged filter, blower problem, or restricted duct system can cause overheating and repeated safety shutdowns.

When Do Heat Strips Turn On?

In Northeast Mississippi, heating demand can change sharply between a mild afternoon and a freezing night. Heat strips give a properly configured system another source of heat when needed. The thermostat and equipment controls determine when they operate.

When the heat pump needs assistance

As outdoor temperatures drop, a house generally loses heat faster. Many heat pumps also produce less heating capacity as temperatures fall, although performance varies by equipment. At some point, the house may need more heat than the heat pump can supply alone.

Auxiliary heat fills that gap. There isn’t one outdoor temperature at which every Tishomingo County system should bring on its strips. Equipment capacity, insulation, duct losses, thermostat programming, and the home’s heating load all matter.

During recovery from a thermostat setback

Picture a Tishomingo homeowner raising the thermostat several degrees on a cold morning after keeping the house cooler overnight. Depending on the controls, that large temperature difference may bring on auxiliary heat even though the heat pump is working.

A steady setting or smaller setback may reduce that recovery demand. Some thermostats manage recovery more gradually. The right approach depends on the system, so repeated strip operation during recovery is worth discussing during HVAC maintenance.

During an outdoor defrost cycle

Cold, damp weather can put frost on a heat pump’s outdoor coil. The system periodically reverses operation to warm that coil and remove the frost. Heat strips may energize during this cycle to temper the indoor air.

Brief auxiliary operation during defrost can be normal. Heavy ice that stays on the outdoor unit, especially with poor indoor heating, calls for inspection.

Auxiliary Heat and Emergency Heat Aren’t the Same Setting

They may use the same resistance heating elements, but the controls use them differently.

  • Auxiliary heat: The system automatically calls for additional heat. The heat pump and strips can operate together when the controls allow it.

  • Emergency heat: On a typical heat pump thermostat, this setting disables normal compressor heating and relies on the backup source. If that source is electric strips, heating can become considerably more electricity-intensive.

Emergency heat isn’t a “warm up faster” button. It’s generally intended for situations where normal heat pump operation is unavailable or inappropriate. Follow the equipment instructions and a technician’s guidance.

Some homes have an air handler paired with a straight air conditioner rather than a heat pump. In that arrangement, electric strips may provide all the home’s central heating instead of serving as backup.

How Much Electricity Do Heat Strips Use?

The installed heat kit’s rating determines its electrical demand. That rating is usually expressed in kilowatts, abbreviated kW. The number of stages operating and how long they stay on determine energy consumption.

Here’s an illustrative calculation—not a specification for your equipment:

  • A heater drawing 10 kW uses 10 kilowatt-hours, or kWh, if it runs continuously for one hour.

  • At a hypothetical electricity rate of $0.15 per kWh, that equals $1.50 for that hour of strip operation.

  • At 240 volts, a 10 kW resistance load draws approximately 42 amps, before accounting for other equipment loads.

These figures illustrate demand, not breaker or wire sizing. Actual electrical requirements come from the equipment nameplate, installation instructions, and applicable electrical rules. Leave that work to qualified professionals.

The blower uses electricity too, and the outdoor unit may be running alongside the strips. Your total heating cost also depends on your utility rate and how much heat the house needs.

Resistance elements convert nearly all their incoming electricity into heat at the element. But a heat pump can deliver more heat per unit of electricity by moving heat from outdoors. That’s why prolonged strip operation generally costs more than supplying the same heat through normal heat pump operation. Duct losses affect how much heat actually reaches the rooms either way.

Normal Backup Operation or a Heating Problem?

An AUX indicator during a freezing morning isn’t automatically a repair issue. What deserves attention is a change from the system’s usual behavior.

Consider a heating inspection if you notice:

  • Auxiliary heat running frequently during relatively mild weather while the house struggles to hold temperature.

  • A substantial increase in electricity use without a similar change in weather, occupancy, or thermostat settings.

  • The outdoor unit remaining inactive through an extended heating call outside a brief defrost cycle.

  • Airflow stopping, breakers tripping, or heat repeatedly cutting out before the house warms up.

Possible causes include a heat pump malfunction, thermostat configuration problems, a failed heating stage, restricted airflow, or a heater relay stuck closed. Leaking ducts or poor insulation can also keep backup heat working longer. One symptom alone won’t identify the cause.

What You Can Safely Check

Start at the thermostat. Confirm that it’s in normal Heat mode rather than Emergency Heat, and note when AUX appears. Record the outdoor temperature and whether you recently changed the setpoint.

Check an accessible filter and replace it if needed, using the correct type and size. Keep supply registers and return grilles unobstructed. From a safe distance, look for heavy ice or debris around the outdoor unit.

You can note whether a labeled breaker has visibly tripped without removing any electrical covers. Don’t repeatedly reset a tripping breaker, open the air handler, or attempt electrical testing. Some air handlers have multiple power supplies; switching off one breaker may leave other circuits energized.

A brief dusty odor at the first heating use can occur. A persistent electrical or melting-plastic smell, smoke, or scorching is different. Stop using the system and seek professional help; if there’s smoke or fire, leave the area and call emergency services.

What a Technician Should Evaluate

A useful diagnosis checks more than whether the elements get hot. A technician can verify the approved heat kit, stage operation, electrical connections, current draw, temperature limits, blower airflow, and thermostat settings. The outdoor heat pump also needs evaluation if backup heat is carrying an unusual share of the load.

A failed heat kit doesn’t automatically require replacing the whole air handler. Repair options depend on equipment condition, compatible parts, electrical damage, and why the failure occurred.

Bottom Line

Heat strips are a useful backup, not something to disable simply because AUX appears. Watch how often they run, whether the house holds temperature, and whether electricity use changes unexpectedly. Harbin Heating & Air Conditioning can inspect heat-strip and heat pump operation for homeowners in Tishomingo and Tishomingo County.

Call Harbin Heating & Air Conditioning at 731-689-3651 or visit us at 5910 Hwy 57, Counce, Tennessee 38326 for help with HVAC replacement, heat pumps, and humidity control in Counce, Shiloh, Pickwick, and the surrounding area.

Brian Williamson

Creative and strategic Website & Graphic Designer with 15+ years of experience in design,
branding, and marketing leadership. Proven track record in team management, visual
storytelling, and building cohesive brand identities across print and digital platforms. Adept at
developing innovative solutions that enhance efficiency, drive sales, and elevate user
experiences.

https://www.limegroupllc.com/
Previous
Previous

What Is a Heat Pump Balance Point? A Winter Guide for Cherokee Homeowners

Next
Next

Why Your Counce Furnace Filter Needs to Fit the Rack Correctly